Proline Prosonic Flow 93P
Ultrasonic flowmeter
Flowmeter for hazardous area installations with a wide range of analog and digital outputs
The Prosonic Flow P clamp-on sensor was specially designed for the process industry. Combined with the Prosonic Flow 93 transmitter with touch control, four-line display and extended functionality, Prosonic Flow 93P offers high accuracy in standard applications.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to DN200
±2% o.r. above DN200 -
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
-
Medium temperature range
DN15 to 65
-40 to +100°C (-40 +212 °F)
-40 to +150°C (-40 +302 °F) option
DN50 to 4000
-40 to +80°C (-40 +276 °F)
-40 to +170°C (-40 +338 °F) option -
Max. process pressure
N/A
-
Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304
-
Quick selection
Individual configuration
-
Benefits
Automatic frequency scan for maximum measuring performance
Increased safety for chemical and petrochemical industry – international hazardous area approvals
Long-term stable signal - maintenance-free permanent mounting from outside with coupling pads
...
-
Field of application
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids and alkalis.
Device properties:
Medium temperature: –40 to...
Documents / Manuals / Software
-
Proline Prosonic Flow 93P
Technical Information
Ultrasonic flow measuring system
Volume flow measurement of liquids in chemical or process applicationsTechnical Information (TI) -
PROSONIC FLOW 93 P
Technical Information
Ultrasonic Flow Measuring System
Volume flow measurement of liquids in chemical or process applications.Technical Information (TI) -
Prosonic Flow 93
FOUNDATION Fieldbus
Operating Instruction
Ultrasonic Flow Measuring System with FOUNDATION Fieldbus interface.
The description of the device functions are in a seperate documentation.Operating Instruction (BA) -
Prosonic Flow 93
HART
Operating Instructions
Ultrasonic Flow Measuring System. The description of the device
functions are in a separate documentation.Operating Instruction (BA) -
Proline Prosonic Flow 93
PROFIBUS DP/PA
Operating Instruction
Ultrasonic Flow Measuring System with PROFIBUS DP/PA interface.
The description of the device functions are in a seperate documentation.Operating Instruction (BA) -
Prosonic Flow 93
HART
Description of Device Functions
Description of the device functions (Options and inputs). Additional
documentation for Operating Instructions PROline Prosonic Flow 93.Operating Instruction (BA) -
Prosonic Flow 93C
FOUNDATION Fieldbus
Description of device functions
Description of the device functions (Options and inputs).
Additional documentation for Operating Instructions Proline Prosonic
Flow 93C FOUNDATION Fieldbus.Operating Instruction (BA) -
Prosonic Flow 93C
FOUNDATION Fieldbus
Operating Instruction
Ultrasonic Flow Measuring System with FOUNDATION Fieldbus interface.
The description of the device functions are in a seperate documentation.Operating Instruction (BA) -
Prosonic Flow 93 PROFIBUS DP/PA
Description of Device Functions
Description of the device functions (Options and inputs).
Additional documentation for Operating Instructions Prosonic Flow93
PROFIBUS DP/PA.Operating Instruction (BA) -
Prosonic Flow 93
FOUNDATION Fieldbus
Description of device functions
Description of the device functions (Options and inputs).
Additional documentation for Operating Instructions Proline Prosonic
Flow 93 FOUNDATION Fieldbus.Operating Instruction (BA) -
Proline Prosonic Flow 90, 91, 93
Sonderdokumentation / Special
Documentation
Montageanleitung für die Verbindung Sensoren / Messumformer bei
Verwendung von flexiblen Kabelschutzrohren
Mounting instruc
tions for the sensor / transmitter connection using flxible conduitShort Instruction (KA)11/06German , English -
Proline Prosonic Flow 93C
Brief Operating Instructions
Ultrasonic flow measuring system
Short Instruction (KA)10/10English -
Proline Prosonic Flow 93
Brief Operating Instructions
Ultrasonic flow measuring system
Short Instruction (KA)07/11English -
Bus plug FF
Installation Instructions
Promag 53, 55, Promag 200, Promass 83, Promass 200, Prowirl 72, 73,
Prowirl 200, Prosonic Flow 92, 93Installation Instructions (EA) -
Replacing amplifier board
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65Installation Instructions (EA) -
Replacing transmitter parts
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Prosonic Flow 90, 93,
t-mass 65, Cubemass 8CN, CNGmass 8DFInstallation Instructions (EA) -
Conversion kits for flexible assignment inputs/outputs
Installation Instructions
Prosonic Flow 93
Installation Instructions (EA) -
I/O-board, subprint, screening sheed
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Installation Instructions (EA) -
Permanent Coupling Pads
Installation Instructions
Prosonic Flow 91W, 93W, P
Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promass 40, 80, 83, 84, Prosonic Flow 93
Installation Instructions (EA) -
Replacing power supply for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 40, 80, 83, 84, CNGmass DCI, Cubemass DCI,
Prosonic Flow 93 PInstallation Instructions (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Installation Instructions (EA) -
Replacing T-DAT
Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 91, 93, t-mass 65Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Mounting set for wall-mount housing
Installation Instructions
Promag 50, 51, 53, 55, Promass 80, 83, 84, Prosonic Flow 90, 93, t-mass
65Installation Instructions (EA) -
Replacing Power supply and display
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Installation Instructions (EA) -
Proline Prosonic Flow 93
PROFIBUS DP/PA
ATEX II2G
Ex documentation
Ex-Dokumentation zur Betriebsanleitung BA076D, BA077D.
Ex documentation for the operating instruction BA076D, BA077D.
Documentation Ex relative à la mise en service BA076D, BA077D.Ex Safety Instructions (XA) -
PROline Prosonic Flow 93
ATEX II3G
Ex documentation
Ex-Dokumentation zur Betriebsanleitung BA070D, BA071D.
Ex documentation for the operating instruction BA070D, BA071D.
Documentation Ex relative à la mise en service BA070D, BA071D.Ex Safety Instructions (XA) -
Prosonic Flow 93
FM/CSA Division 1
Ex documentation for the Prosonic Flow operating instructions
Ex Safety Instructions (XA) -
Proline Prosonic Flow 93P
JPN:Zone 1(Ex d バージョン)
安全上の注意事項
危険場所における電気機器の安全上の注意事項
Ex Safety Instructions (XA) -
PROline Prosonic Flow 93
FOUNDATION Fieldbus
ATEX II2G
Ex documentation
Ex-Dokumentation zur Betriebsanleitung BA070D, BA071D.
Ex documentation for the operating instruction BA070D, BA071D.
Documentation Ex relative à la mise en service BA070D, BA071D.Ex Safety Instructions (XA) -
PROline Prosonic Flow 93 P
FM/CSA Div.1
Ex
documentation
Ex documentation for the operating instruction BA076D, BA077D.<
Ex Safety Instructions (XA) -
Prosonic Flow 93
ATEX II3G
Ex-Dokumentation zur Betriebsanleitung Prosonic Flow 93
Ex
documentation for the Prosonic Flow operating instructions
Documentation Ex relative aux instructions de mise en service Prosonic Flow 93Ex Safety Instructions (XA) -
PROline Prosonic Flow 93
FM/CSA Div. 1
Ex
documentation
Ex-Dokumentation zur Betriebsanleitung BA070D, BA071D.
Ex documentation for the operating instruction BA070D, BA071D.
Documentation Ex relative à la mise en service BA070D, BA071D.Ex Safety Instructions (XA) -
Proline Prosonic Flow 93
HART
ATEX II2G
Ex
documentation
Ex-Dokumentation zur Betriebsanleitung BA070D, BA071D.
Ex documentation for the operating instruction BA070D, BA071D.
Documentation Ex relative à la mise en service BA070D, BA071D.Ex Safety Instructions (XA) -
PROline Prosonic Flow 93 P
FM/CSA Div.1
Ex
documentation
Ex documentation for the operating instruction BA078D, BA079D.<
Ex Safety Instructions (XA) -
PROline Prosonic Flow 93 P/W
PROFIBUS-PA/-DP
ATEX II
3G
Ex documentation
Ex-Dokumentation zur Betriebsanleitung BA076D, BA077D.
Ex documentation for the operating instruction BA076D, BA077D.
Documentation Ex relative à la mise en service BA076D, BA077D.Ex Safety Instructions (XA) -
Proline Prosonic Flow 93
ATEX II2GD
IECEx Zone 1/21
Ex documentation
Ex-Dokumentation zur Betriebsanleitung Prosonic Flow 93
Ex documentation for the Prosonic Flow 93 operating instructions
Documentation Ex relative aux instructions de mise en service Prosonic
Flow 93Ex Safety Instructions (XA) -
Proline Prosonic Flow 93
NEPSI Zone 1, Zone 21
Ex documentation
Ex-Dokumentation zur Betriebsanleitung:
Ex documentation for operating instructions:
Ex relative aux instructions de mise en service:
BA00070D, BA00076D, BA00078DEx Safety Instructions (XA) -
PROline prosonic flow 93 (PROFIBUS-DP/-PA)
Sonderdokumentation
/ Additional documentation
Zusatzdokumentation zur Software-Version V 1.06.XX (Messverstärker) / V
2.03.00 (Kommunikation);
gültig für: BA077D/06/de/12.02
Additional documentation for software version V 1.06.XX (amplifier) / V
2.03.00 (communication);
valid for: BA077D/06/en/12.02Special Documentation (SD) -
Proline Prosonic Flow 92F/93, t-mass 65, Promag 53/55, Promass 83,
Prowirl 72/73
Special Documentation
Supplementary information to following modifications: Bus plug wiring
configuration for FOUNDATION Fieldbus devicesSpecial Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Interoperability Statement: Prosonic Flow 93, FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Prosonic Flow 93, FOUNDATION fieldbus Flow Transmitter, Device Revision:
1, DD Revision: 3, Device ID: 0x1059, Software Revision: 1.01Special Documentation (SD) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 PROFIBUS DP: 3.06.00Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 FOUNDATION Fieldbus:
4.00.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 PROFIBUS PA: 2.03.01Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 HART: 2.02.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 HART: 2.03.01Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 HART: 2.02.01Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 PROFIBUS DP: 3.06.10Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 HART: 2.00.00Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 FOUNDATION Fieldbus:
1.01.02Manufacturer Information (MI) -
Prosonic Flow 93
Manufacturer Information (NE53)
New Software Version:
Prosonic Flow 93 FOUNDATION Fieldbus:
3.00.01Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Proline Promag 23
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 23 HART: 2.02.01 (DE/EN) / 2.03.01
(FR/IT)Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 HART: 2.01.00Manufacturer Information (MI) -
Proline Prosonic Flow 93
Manufacturer information regarding
software updates (NE 53)
New software version:
Prosonic Flow 93 FOUNDATION Fieldbus:
2.00.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Proline Promag 53
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 53 PROFIBUS DP: 3.06.00Manufacturer Information (MI) -
Kosztowne pomiary przeplywu
Pomiar przepływu bez strat ciśnienia
Publications (PU)12/13Polish -
Kosztowne pomiary przepływu- NiS_01_2012
Sieci wodociągowe, układy zasilania kotłów parowych w wodę,
rurociągi paliwowe – to przykładowe instalacje, w których do pomiaru
przepływu chętnie używa się tradycyjnych metod, bazujących na
różnicy ciśnień. Dzięki nowszym metodom pomiaru przepływu cieczy
koszty te można w łatwy sposób wyeliminować.Publications (PU)04/12Polish -
Pomiary przepływu apa_05_2011
Zastosowanie w procesach przemysłowych nowoczesnej
i nieinwazyjnej ultradźwiękowej technologii pomiaru przepływu, która
oparta jest na pomiarach czasu przejścia fali ultradźwiękowej.Publications (PU)03/12Polish -
Durchflusserfassung von Salzsäure bei Dyneon
Applikationen prosonic flow
Branche ChemieIndustry Solutions (SO)German -
Brewery application: Brewhouse, Application 9
Meas. point 8: flow measurement wort
Application 1: ultrasonicIndustry Solutions (SO)English -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Ultraschall-Durchflussmessung von außen: Kostengünstig – flexibel –
robust
Clamp-on-Messtechnologie
KompetenzbroschüreCompetence Brochure (CP)05/10German -
Flow measurement from outside the pipe: Cost-effective – flexible –
robust
Ultrasonic clamp-on technology
Competence brochureCompetence Brochure (CP)05/10English -
Boiler water flow measurements with Prosonic a "snap"
Prosonic ultrasonic system measures in boiler water flow applications
Case Studies (CS)07/10English -
Case Study: Go with the flow and get clamping!
Prosonic 93P clamp-on ultrasonic flowmeter on formaldehyde pipes
Case Studies (CS)04/05English -
Cost transparency through energy monitoring
Data collection and visualization of the energy consumption.
Case Studies (CS)01/13English -
Innovation Brochure
Proline Prosonic Flow 93P
Ultrasonic flow measurement
Simple reliable flexibleInnovations (IN)09/09Japanese -
Prosonic Flow 91W / 93W / 93P
Now with a “coupling pad” for reliable sound transmission and maximum
performance during clamp-on flow measurementInnovations (IN)07/19English -
Prosonic Flow 91W / 93W / 93P
Maintenant avec un "patin de couplage" pour une transmission fiable du
son et des
performances maximales lors de la mesure de débit clamp-onInnovations (IN)07/19fr -
Prosonic Flow 91W / 93W / 93P
Jetzt mit “Koppelpad” für die sichere Schallübertragung und höchste
Performance bei der Clamp-on-DurchflussmessungInnovations (IN)07/19German -
Proline Prosonic Flow 93P
Ultrasonic flow measurement: Simple - reliable - flexible
Innovations (IN)04/09English -
Proline Prosonic Flow 93P
Ultraschall-Durchflussmessung: Einfach – sicher – flexibel
Innovations (IN)04/09German -
GSD Single, GSD_EH_PA_FL_Prosonic_Flow_0x1530_V03_05_00_PALIB, 22.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.06.00Language neutral -
GSD Single, GEH_EH_PA_FL_Prosonic_Flow_0x1530_V02_01_00_PALIB, 22.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.10.00Language neutral -
GSD Single, GSD_EH_DP_FL_Prosonic_Flow_0x1531_V02_03_00_DPLIB, 17.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.03.00Language neutral -
GSD Single, GSD_EH_PA_FL_Prosonic_Flow_0x1530_V02_00_01_PALIB, 22.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.01Language neutral -
GSD Single, GSD_EH_DP_FL_Prosonic_Flow_0x1531_V02_00_01_DPLIB, 17.04.2014
(Flow, Prosonic Flow, 0x1
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.01Language neutral -
EDD Single, EH_FF_FL_ProsonicFlow_93_0x1059_0x02_0x01, 07.04.2014 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)2.00.00Language neutral -
EDD Single, PDM_DP_FL_ProsonicFlow_0x1531_0x05_0x01, 17.01.2019 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_FF_FL_ProsonicFlow_0x1059_0x04_0x01, 11.04.2017 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_FL_ProsonicFlow93_0x1059_0x03_0x01_ITK5_01, 09.11.2016
(Flow, Prosonic Flow, 0x10
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow93_0x1530_0x02_0x01, 30.01.2019 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_ProsonicFlow93_0x1531_0x02_0x01, 30.01.2019 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_FL_ProsonicFlow93_0x1059_0x01_0x01_ITK4_01, 09.11.2016
(Flow, Prosonic Flow, 0x10
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_FL_ProsonicFlow_0x1059_0x04_0x01, 11.04.2017 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow93_0x1530_0x05_0x01, 25.01.2019 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x04_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x05_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow93_0x1530_0x03_0x01, 25.01.2019 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlow_0x0059_0x08_0x01, 21.08.2019 (Flow, Prosonic Flow, 0x0059)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_ProsonicFlow_0x0059_0x08_0x01, 21.08.2019 (Flow, Prosonic Flow, 0x0059)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x06_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x02_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_ProsonicFlow_0x1059_0x04_0x04, 07.04.2014 (Flow, Pr
osonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x07_0x01, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x03_0x02, 14.11.2018 (Flow, Prosonic Flow, 0x0059)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_ProsonicFlow93_0x1530_0x06_0x02, 30.01.2019 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
PDM Version: 6.0 SP5, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_5_FF_FL_ProsonicFlow_0x1059_0x04_0x01, 11.04.2017 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_FL_ProsonicFlow93_0x1059_0x01_0x03_ITK4_60, 09.11.2016
(Flow, Prosonic Flow, 0x10
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow93_0x0059_0x08_0x03, 05.08.2015 (Flow, Prosonic Flow)
HART,
PDM Version: 6.0 SP5, 6.1, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_ProsonicFlow93_0x1531_0x03_0x01, 25.01.2019 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow_93_FF_FW4_00_zz_Dev_Rev_4, 22.10.2020 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, ProsonicFlow_93_FF_FW3_00_zz_Dev_Rev_3, 22.10.2020 (Flow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, ProsonicFlow_93_PA_V2_00_01___V2_02_02, 21.10.2020 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_DP_V2_03_00, 19.10.2020 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_DP_V3_06_xx, 19.10.2020 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_PA_V3_05_xx, 21.10.2020 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_PA_V3_06_xx, 21.10.2020 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_DP_V2_00_01___V2_02_02, 19.10.2020 (Flow, Prosonic Flow, 0x1531)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_PA_V2_03_00, 21.10.2020 (Flow, Prosonic Flow, 0x1530)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, ProsonicFlow_93_V1_06_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_HART_FW2_03_zz_Dev_Rev_8, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_V2_00_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_V2_02_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_V1_04_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_V2_01_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicFlow_93_V1_05_0x, 26.10.2020 (Flow, Prosonic Flow, 0x0059)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Flow_1_05_00, 22.07.2015 (Flow)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_FF_FL_ProsonicFlow_0x1059_0x04_0x04, 07.04.2014 (Fl
ow, Prosonic Flow, 0x1059)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.10Faceplate1.00.00Language neutral -
Prosonic Flow Clamp on
Installation Video
This video will guide you through the basic steps of programming and
installing the Prosonic Flow clamp-on flowmeter.Animation11/07English -
Product Family: Prosonic Flow 93
Product Code: 93W-, 93P-, 93C-, 93U-
Declaration Number: IT041500Manufacturer DeclarationEnglish -
Prosonic Flow 90, Prosonic Flow 93, Prosonic Flow DDU 18, Prosonic Flow DDU 19
Product Code: 90P-, 90U-, 90W-, 93C-, 93P-, 93U-, 93W-, DDU18-, DDU19-
Declaration Number: EC_00305_01.16EU DeclarationGerman , English , fr -
Prosonic Flow 90, Prosonic Flow 93, Prosonic Flow DDU 18, Prosonic Flow DDU 19
Product Code: 93W-, 93P-, 90W-, 90P-
EU DeclarationGerman , English , fr -
Prosonic Flow 93, Prosonic Flow DDU 18, Prosonic Flow DDU 19
Product Code: 93P-, DDU18-, DDU19-
Declaration Number: EC_00306_02.16EU DeclarationGerman , English , fr -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 93
Product Code: 91W-, 93C-, 93P-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 93
Product Code: 91W-, 93C-, 93P-, 93W-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU C-D.CH.AL32.B.05672MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, PROSONIC FLOW E
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-, 9E1B-, 9EHB-
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 90P-, 93P-, 93W-, 93C-, 93U-, 90U-, 90W-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/, II/1/E,F,G/Explosion ProtectionEnglish -
Prosonic Flow 93
Product Code: 93P-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia], Ex ib, Ex d [ia Gb] [ia Ga]Explosion ProtectionEnglish -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 93P-, 90P-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G
Protection: Ex tb [ia], Ex tb [ia Db] [ia Da], Ex db ebExplosion ProtectionEnglish -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Prosonic Flow 92, Prosonic Flow 93
Product Code: 92F-, 93P-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d [ia], Ex d e [ia], Ex ia, Ex ib, Ex tb [ia], Ex d [ia Gb] [ia Ga], Ex tb [ia Db] [ia Da]Explosion ProtectionRussian -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 90P-, 93P-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21
Protection: Ex d [ia], Ex d e [ia]Explosion ProtectionEnglish , Chinese -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 90P-, 93P-
Region/Country: USA
Approval Agency: FMExplosion ProtectionEnglish -
Prosonic Flow 93
Product Code: 93P-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G/Explosion ProtectionEnglish -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 93P-, 90P-
Region/Country: International (IECEx)
Approval Agency: EXAM (DMT, BVS)
Protection: Ex db eb, Ex tb [ia], Ex tb [ia Db] [ia Da]Explosion ProtectionEnglish -
Prosonic Flow 90, Prosonic Flow 93, Prosonic Flow DDU 18, Prosonic Flow DDU 19
Product Code: 90P-, 93P-, DDU18-, DDU19-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionEnglish -
Prosonic Flow 93
Product Code: 93C-, 93P-, 93U-, 93W-
Region/Country: USA
Approval Agency: FMExplosion ProtectionEnglish -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 90P-, 93P-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEnglish -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTLExplosion Protection -
Prosonic Flow 93
Product Code: 93P-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d [ia]Explosion Protection -
Prosonic Flow 93
Product Code: 93C-, 93P-, 93W-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0Fieldbus ConformanceEnglish -
Product Family: Prosonic Flow 93
Product Code: 93C-, 93P-, 93W-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 03, DD-ITK 5.01Fieldbus ConformanceEnglish -
Prosonic Flow 93
Product Code: 93C-, 93P-, 93W-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 04, DD-ITK 6Fieldbus ConformanceEnglish -
Prosonic Flow 90, Prosonic Flow 93
Product Code: 93W-, 93U-, 93P-, 93C-, 90P-, 90U-, 90W-
Region/Country: PolandPressure EquipmentEnglish , Polish -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 93P-, 93C-, 93W-, 92F-, 91W-
Region/Country: Russia (GOST)
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 48356_1MetrologyRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 91W-, 92F-, 93C-, 93P-, 93TA1-, 93W-
Approval Agency: RM RSMarineRussian -
Prosonic Flow 93
Product Code: 93P-, 93W-
Region/Country: International
Approval Agency: RINAMarineEnglish -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93
Product Code: 93P-, 93C-, 93W-, 91W-, 92F-, 93TA1-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Prosonic Flow 93
Product Code: 93P-, 93W-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Prosonic Flow 93
Product Code: 93P-, 93W-
Region/Country: International
Approval Agency: BVMarineEnglish
Accessories / Spare parts
-
-
Nr F Order code 50099250
Kit power s.b. PSONIC9X 85-260VAC
-
Nr F Order code 71243440
-
Nr F Order code 50099252
Kit P.s.b. PSONIC9X 20-55VAC16-62VDC
-
Nr F Order code 50099251
Kit power s.b. PSONIC9X 85-260VAC Ex
-
Nr F Order code 50099253
Kit P.s.b. PSONIC9X 20-55VAC16-62VDC Ex
-
-
-
Nr 7 Order code 50094002
Kit 10 fuses 250 VAC T800 MA
-
Nr 7 Order code 50094003
Kit 10 fuses 250 VAC T 2A00
-
-
-
Nr B Order code 71093780
-
Nr B Order code 71093781
-
Nr B Order code 71093783
-
Nr B Order code 71093785
-
Nr B Order code 71093786
-
Nr B Order code 71093787
-
Nr B Order code 71093788
-
Nr B Order code 71093789
-
Nr B Order code 71093790
-
Nr B Order code 71093791
-
Nr B Order code 71093792
-
Nr B Order code 71093793
-
-
-
Nr C Order code 50098301
Kit com 53/55/83/93 curr./freq. out Ex
-
Nr C Order code 50098300
-
Nr C Order code 71066579
-
Nr C Order code 71107614
Kit I/O 93 Profibus DP C13 Ex
-
-
-
Nr D Order code 50108002
-
-
-
Nr C Order code 50101264
-
Nr C Order code 71095035
-
Nr C Order code 50101264
-
Nr C Order code 71095035
-
Nr C Order code 50098302
-
Nr C Order code 50098303
-
-
-
Nr D Order code 50096833
-
-
-
Nr 3 Order code 50096834
-
Nr 3 Order code 50096834
-
-
-
Nr 4 Order code 50096835
-
Nr 4 Order code 50096835
-
-
-
Nr 6 Order code 50096836
-
Nr 6 Order code 50096836
-
-
-
Nr 5 Order code 50096837
-
-
-
Nr E Order code 50096755
-
-
-
Nr G Order code 50096754
-
-
-
Nr 10 Order code 50094017
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
-
-
-
Nr 8 Order code 50094014
Kit connec. board In/Output Wall encl
-
-
-
Nr 9 Order code 50099256
Kit connec.plate 90/93 1CH wall enclo.
-
Nr 9 Order code 50099257
Kit connec.plate 93 2CH wall enclo.
-
-
-
Nr 16 Order code 71008445
Kit Terminal protective Cover Ex
-
-
-
Nr 30 Order code 50108140
Kit Termin.Block Wall encl. 5X/8X/9X/65
-
-
-
Nr 2 Order code 50094004
Kit T-DAT Transmitter Data Chip
-
-
-
Nr 17 Order code 50094027
Kit Cover 5X/40/8X/93/65 with window Exd
-
-
-
Nr 18 Order code 50094029
Kit Cover 5X/40/8X/93/65 vers. blind Exd
-
-
-
Nr 21 Order code 50094038
-
-
-
Nr 19 Order code 50094039
Kit Cover 5X/40/8X/93/65 Conn.termi.Exe
-
-
-
Nr 20 Order code 50094040
Kit Cover 5X/40/8X/93/65 Conn.termi.Exd
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
-
-
Nr 12 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 12 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 12 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 12 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 12 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 12 Order code 50094984
Kit Cable gland Found. Fieldbus
-
-
-
Nr 14 Order code 50096839
Kit Circuit board cpl field/SS-housing
-
-
-
Nr 13 Order code 50096841
Kit Ground terminal / Cover clamp
-
-
-
Order code 50096838
Kit 2 Screening sheet field housing
-
Order code 50098636
Kit 2 Screening sheet wall enclo.
-
-
-
Nr 11 Order code 50094041
Kit Seal cover to Wall enclosure
-
-
-
Nr 22 Order code 50094050
Kit 10 Seal cover to field housing
-
-
-
Order code FXA193-??
Serviceinterface FXA193
-
Order code DK9UI-???
Prosonic Flow 93, retro fit kit In/Out
-
Order code 50091703
Sensor pair-40...80oC Prosonic F DDU18
Sound velocity measuring sensors for Prosonic Flow 93; sensor pair for measurement of sound velocity in the fluid.
-
Order code 50091704
Sensor pair0...170oC Prosonic F DDU 18
Sound velocity measuring sensors for Prosonic Flow 93; sensor pair for measurement of sound velocity in the fluid.
-
Order code 50091713
Sensor 0...60oC Prosonic Flow DDU 19
Wall thickness measuring sensor for Prosonic Flow 93P and 93W; sensor for measuring pipe wall thickness.
-
Order code
Overview auxiliary equipment see spare part picture
-
Order code 93XXX-
Prosonic Flow 93, transmitter
-
Order code DK9PS-
-
Order code DK9SS-
Prosonic Flow 91/93/93T,sensor cable set
-
Order code DK9SH-
Prosonic Flow W/P, sensor holder set
-
Order code DK9IC-
Prosonic Flow W/P, install.set Clamp On
Only use with Prosonic Flow 91 and 93 transmitter.
-
Order code DK9CB-
Prosonic Flow 91/93 W/P, conduit adapter
-
Order code DK9WM-
Transmitter 91/90/93, Mounting set
-
Order code DK9SO-
-
Order code DK9CM-
-
-
Predecessor