%20Insertion%20version%20-%20PP01.jpg) 
                  Specs at a glance
- 
                              Max. measurement errorGas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.) 
- 
                              Measuring range20 to 733501 kg/h (44 to 1669340 lb/h) 
- 
                              Medium temperature range-40 °C to +180°C (-40 °F to +356°F) 
- 
                              Max. process pressure-0.5 to 20 bar_g (-7.25 to 290 psi_g) 
- 
                              Wetted materialsMaterials for insertion tube 
 Stainless steel, 1.4404 (316/316L)
 Process connections, process coupling
 Stainless steel, 1.4404 (316/316L)
 Sensing element
 Unidirectional
 Stainless steel, 1.4404 (316/316L)
 Alloy C22, 2.4602 (UNS N06022);
 Bidirectional
 Stainless steel, 1.4404 (316/316L)
 Reverse flow detection
 Stainless steel, 1.4404 (316/316L)
 Clamping rings
 PEEK
 PVDF
 1.4404 (316/316L)
 Flat ring seal
 EPDM
 FKM
Field of application
The patented sensor design of t-mass I provides unprecedented measurement stability in thermal insertion mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter of t-mass I 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement 
- Measurement of utility and process gases and gas mixtures in circular piping or rectangular ducts 
Device properties
- Insertion version for DN 80 to 1500 (3 to 60") 
- Bidirectional measurement; high measuring performance 
- Patented drift-free sensor with SIL 2 
- Remote version with up to 4 I/Os 
- Backlit display with touch control and WLAN access 
- Standard cable between sensor and transmitter 
Benefits
- Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof 
- High level of process control – premium measurement accuracy and repeatability 
- Reliable monitoring – detection of process disturbances and reverse flow 
- Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts 
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses 
- Reduced complexity and variety – freely configurable I/O functionality 
- Integrated verification – Heartbeat Technology 
Videos
Extended selection
- 
        High-end products 
- Highly functional and convenient
Technical excellence
Simplicity
 
                              - 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity | 
|---|---|---|
| 
 Fundamental selection Meet your basic measurement needs | Technical excellence | Simplicity | 
| 
 Lean selection Handle your core processes easily | Technical excellence | Simplicity | 
| 
 Extended selection Optimize your processes with innovative technologies | Technical excellence | Simplicity | 
| 
 Xpert selection Master your most challenging applications | Technical excellence | Simplicity Variable | 
Predecessor
- 
                        - 
                                                            Technical Information (TI)
 TI Proline t-mass I 500Thermal mass flowmeter EN 28/07/202305/07/202117/09/2020Language: English Version: 28/07/2023 File size: 5.5 MB File name: TI01503DEN_0323-00.pdf 
- 
                                                            
- 
                        - 
                                                            Operating Instruction (BA)
 BA Proline t-mass I 500Thermal mass flowmeter 
 HARTEN 28/07/202305/07/202117/09/2020Language: English Version: 28/07/2023 File size: 7.4 MB File name: BA01997DEN_0323-00.pdf 
- 
                                                            
- 
                        - 
                                                            Operating Instruction (BA)
 BA Proline t-mass I 500Thermal mass flowmeter 
 Modbus RS485EN 28/07/202305/07/202117/09/2020Language: English Version: 28/07/2023 File size: 6.7 MB File name: BA01999DEN_0323-00.pdf 
- 
                                                            
- 
                        - 
                                                            Device Parameter (GP)
 Proline t-mass 500 HARTThermal mass flowmeter EN 01/07/202117/09/2020Language: English Version: 01/07/2021 File size: 2.1 MB File name: GP01145DEN_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Device Parameter (GP)
 GP Proline t-mass 500 Modbus RS485Thermal mass flowmeter EN 15/03/202401/07/202117/09/2020Language: English Version: 15/03/2024 File size: 2.5 MB File name: GP01146DEN_0324-00.pdf 
- 
                                                            
- 
                        - 
                                                            Short Instruction (KA)
 Proline t-mass IThermal mass flow sensor EN 05/07/202117/09/2020Language: English Version: 05/07/2021 File size: 1 MB File name: KA01443DEN_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Short Instruction (KA)
 Proline 500 – digital Modbus RS485Transmitter with thermal mass flow sensor EN 05/07/202117/09/2020Language: English Version: 05/07/2021 File size: 1.7 MB File name: KA01447DEN_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Short Instruction (KA)
 Proline 500 – digital HARTTransmitter with thermal mass flow sensor EN 05/07/202117/09/2020Language: English Version: 05/07/2021 File size: 1.3 MB File name: KA01446DEN_0221.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 EA Replacing Small PartsProline 10, 400, 500, 500-digital, 800 Index B, 800 Index C, Cubemass EN 01/01/202415/12/202101/05/202101/04/202101/06/2020Language: English Version: 01/01/2024 File size: 1.2 MB File name: EA01024DA2_1223-00.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 EA Replacing the Display ProtectionProline 400, 800 Index C, 500-digital EN 01/01/202415/12/202101/06/202002/08/201901/03/2018Language: English Version: 01/01/2024 File size: 480 KB File name: EA01093DA2_0723-00.pdf 
- 
                                                            
%20Insertion%20version%20-%20PP01.jpg) 
                                             
                                             
                                             
                               
                                   
                                     
                                    .jpg) 
                                     
                                   
                                   
                                   
                                   
                                   
                                  