Specs at a glance
-
Measured variables
CO2, SO2, NO, NO2, CO, NH3, H2O, CH4
-
Ambient temperature range
0 °C ... +50 °C
Type approved up to 45 °C -
Conformities
MARPOL Annex VI and NTC 2008 – MEPC.177(58)
Guidelines for exhaust gas cleaning systems – MEPC.340(77)
Guidelines for SCR reduction systems – MEPC.198(62)
DNV Rules for Type Approvals (2012)
IACS E10 and Rules of major classification societies
Field of application
The MARSIC300 ship emissions measuring device is a customized solution for reliably measuring emissions on ships according to MARPOL Annex VI and IMO MEPC. The MARSIC300 is type-approved for this application by well-known classification organizations. The MARSIC300 measures both SOx and CO2 upstream and downstream of the scrubbers, and NOx upstream and downstream of SCR plants. The measuring device impresses with extremely low maintenance costs and modules that are easy to replace.
Reliable emission monitoring on ships
Accurate DeNOx and DeSOx measurements for ship engines
Cost-efficient process monitoring of the scrubber and catalytic converters
Device properties:
Rugged design and high level of measurement accuracy
Type-approved by well-known classification organizations in accordance with MARPOL Annex VI and IMO MEPC
Measuring ranges adapted to low and high concentrations of SO2 and NOx
Up to 8 measuring components at the same time: SO2, CO2, CO, NO, NO2, NH3, H2O, CH4
Benefits
Modules that are easy to replace during servicing
Low costs thanks to minimal maintenance requirements
Extensive network for service support
Quick access to expert support with remote maintenance
No expensive test gases thanks to its certified internal drift correction
Also equipped for new requirements thanks to its rugged design and high level of measurement accuracy
Videos
-
MARSIC300: Maritime emission monitoring
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
NDIR spectroscopy
-
Measured variables
CO2, SO2, NO, NO2, CO, NH3, H2O, CH4
-
Measuring range
CO2: 0 ... 25 Vol.-%
SO2: 0 ... 30 ppm / 0 ... 2,000 ppm
NO: 0 ... 300 ppm / 0 ... 2,000 ppm
NO2: 0 ... 200 ppm / 0 ... 500 ppm
CO: 0 ... 200 ppm / 0 ... 2,000 ppm
NH3: 0 ... 50 ppm / 0 ... 500 ppm
CH4: 0 ... 500 ppm / 0 ... 10,000 ppm
H2O: 0 ... 40 Vol.-% -
Process temperature
+10 °C ... +550 °C
-
Process pressure
–20 hPa ... 200 hPa
Relative -
Ambient temperature range
0 °C ... +50 °C
Type approved up to 45 °C -
Ambient humidity
≤ 90 %
Non-condensing -
Conformities
MARPOL Annex VI and NTC 2008 – MEPC.177(58)
Guidelines for exhaust gas cleaning systems – MEPC.340(77)
Guidelines for SCR reduction systems – MEPC.198(62)
DNV Rules for Type Approvals (2012)
IACS E10 and Rules of major classification societies -
Degree of protection
IP54
-
Product safety
CE, Rules of major classification societies
-
-
Technical Information (TI)
MARSIC300, Installation and Initial Start-up
-
Technical Information (TI)
English version - 10/2025New version available in EnglishShip Emission Measuring Device (Technical Information)
EN 01/10/202501/01/2025Language:
English
Version:
01/10/2025
File size:
7.6 MB
File name:
8030681_1TM0_TI_MARSIC300_en_V4-0_2025-10_EHS.pdf
-
-
-
Operating Instruction (BA)
SFU weatherproof enclosure
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Sampling Unit with Weatherproof Enclosure
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
-
-
-
Operating Instruction (BA)
SFU
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Sampling Unit
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
-
-
-
Operating Instruction (BA)
SFU100, SFU150
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Sampling Unit for maritime applications
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029814_AE00_OI_SFU100_SFU150_en_V1-0_2024-09_EHS.pdf
-
-
-
Operating Instruction (BA)
MARSIC300
-
Operating Instruction (BA)
English version - 08/2025New version available in EnglishShip Emission Measuring Device
EN 01/08/202501/01/2025Language:
English
Version:
01/08/2025
File size:
13.6 MB
File name:
8029898_1TM0_OI_MARSIC300_en_V4-1_2025-08_EHS.pdf
-
-
-
Short Instruction (KA)
MARSIC300 Quickstart
-
Short Instruction (KA)
English version - 01/2025New version available in EnglishQuickstart guide to commission the product quickly
and easily and to achieve initial measurement resultsLanguage:
English
Version:
01/01/2025
File size:
4 MB
File name:
8031190_AE00_KA_MARSIC300_en_V1-0_2017-09_EHS.pdf
-
-
-
Short Instruction (KA)
Condensate Container for analyzer solutions
-
Short Instruction (KA)
English version - 01/2025New version available in EnglishThe use of the condensate container is to collect condensate
within the gas outlet in order to prevent condensate formation in
the direct environment of the measuring device.EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
1.1 MB
File name:
8029822_AE00_KA_Condensate_Container_en_V1-0_2019-02_EHS.pdf
-
-
-
Short Instruction (KA)
Conditioning of Instrument Air for Analyzer Solutions
-
Short Instruction (KA)
English version - 01/2025New version available in EnglishThe intended use of the Instrument Air Conditioning Unit is to supply a
measuring device with clean, filtered and conditioned instrument air.EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.3 MB
File name:
8029824_AE00_KA_Instrument_Air_Conditioning_en_V1-0_2019-03_EHS_WEB.pdf
-
-
-
Installation Instructions (EA)
MARSIC300 - Cooling Device
-
Installation Instructions (EA)
English version - 01/2025New version available in EnglishRetrofit Instructions that describe the service work
required for installation of a new cooling deviceLanguage:
English
Version:
01/01/2025
File size:
3 MB
File name:
8031263_1HKV_EA_MARSIC300_en_V2-0_2023-01_EHS.pdf
-
-
-
Installation Instructions (EA)
MARSIC300 - Cooling Device
-
Installation Instructions (EA)
English version - 01/2025New version available in EnglishInstallation Instructions
Language:
English
Version:
01/01/2025
File size:
2.7 MB
File name:
8031263_1HKV_EA_MARSIC300_en_V2-0_2023-01_EHS.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons