Proline Promag 53E
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag 53E ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

The economical flowmeter with flexible system integration

Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the Promag 53 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, electrode cleaning or advanced diagnostics, Promag 53E offers highest accuracy in the most complex and demanding measuring tasks. Promag 53E is available as compact or remote version.

This product is not available in this market.

  • Benefits

    • Cost-effective sensor – ideal solution for basic requirements

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Quality – software for filling & dosing, density, electrode cleaning...

  • Field of application

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Fully suitable for basic applications in the chemical and process industry

    Device properties

    • Nominal diameter: max. DN 600 (24")

    • Ex approvals...

Features and specifications

Back

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The economical flowmeter with flexible system integration. Fully suitable for basic applications in the chemical and process industry.

  • Sensor features

    Cost‐effective sensor – ideal solution for basic requirements. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). Ex approvals for Zone 2.

  • Transmitter features

    Quality – software for filling & dosing, density, electrode cleaning and also advanced diagnostics. Easy calculation – bidirectional totalizers. Automatic recovery of data for servicing. 4-line backlit display with touch control. Device as compact or remote version.

  • Nominal diameter range

    DN 15 to 600 (½ to 24")

  • Wetted materials

    Liner: PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

  • Measured variables

    Volume flow

  • Max. measurement error

    Volume flow: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

  • Max. process pressure

    PN 40, Class 150, 20K

  • Medium temperature range

    –10 to +110 °C (+14 to +230 °F)

  • Ambient temperature range

    –10 to +60 °C (+14 to +140 °F)

  • Sensor housing material

    DN 15 to 300 (½ to 12"): AlSi10Mg, coated

    DN 350 to 600 (14 to 24"): Carbon steel with protective varnish

    Sensor connection housing: AlSi10Mg, coated

  • Transmitter housing material

    Powder‐coated die‐cast aluminum

  • Degree of protection

    Compact version: IP67, type 4X enclosure
    Sensor remote version (standard): IP67, type 4X enclosure
    Sensor remote version (option): IP68, type 6P enclosure
    Transmitter remote version: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency (passive)
    Relay output
    Switch output (passive)

  • Inputs

    2 modular inputs:
    Status input
    0‐20 mA (aktiv)/4‐20 mA (aktiv/passiv)

  • Digital communication

    HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, MODBUS RS485, EtherNet/IP

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, cCSAus

  • Product safety

    CE, C-tick, EAC marking

  • Metrological approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED

  • Material certificates

    3.1 material

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • F
  • 7
  • B
    • Nr B Order code 50106085

      Kit meas. amplifier PMAG 53 WEA

      Language: FR, ES, IT, NL, PT, DE, EN

    • Nr B Order code 71039454

      Kit meas. amplifier 53 WEA HE

      Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment

    • Nr B Order code 50106087

      Kit meas. amplifier PMAG 53 SEA

      Language: JA, ID, EN

    • Nr B Order code 71039456

      Kit meas. amplifier 53 SEA HE

      Language: JA, ID, EN HE = harsh environment

    • Nr B Order code 50106086

      Kit meas. amplifier PMAG 53 EES

      Language: SV, FI, NO, RU, PL, CS, EN

    • Nr B Order code 71039455

      Kit meas. amplifier 53 EES HE

      Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment

    • Nr B Order code 50108133

      Kit meas. amplifier Pmag 53 CN

      CN= language ZH + EN

    • Nr B Order code 71039457

      Kit meas. amplifier 53 CN HE

      Language: ZH, EN HE = harsh environment

    • Nr B Order code 71261680

      Kit amp. 53, HART7, DE+FR+IT+ES+EN

      Language: DE+FR+IT+ES+EN

    • Nr B Order code 71261682

      Kit amp. 53, HART7, DE+FR+IT+ES+EN, HE

      Language: DE+FR+IT+ES+EN HE = harsh environment

    • Nr B Order code 71261686

      Kit amp. 53, HART7, RU+NL+PT+CS+EN

      Language: RU+NL+PT+CS+EN

    • Nr B Order code 71261687

      Kit amp. 53, HART7, RU+NL+PT+CS+EN, HE

      Language: RU+NL+PT+CS+EN HE = harsh environment

    • Nr B Order code 71261690

      Kit amp. 53, HART7, ZH+PL+ID+EN

      Language: ZH+PL+ID+EN

    • Nr B Order code 71261692

      Kit amp. 53, HART7, ZH+PL+ID+EN, HE

      Language: ZH+PL+ID+EN HE = harsh environment

    • Nr B Order code 71261693

      Kit amp. 53, HART7, JA+SV+NO+FI+EN

      Language: JA+SV+NO+FI+EN

    • Nr B Order code 71261694

      Kit amp. 53, HART7, JA+SV+NO+FI+EN, HE

      Language: JA+SV+NO+FI+EN HE = harsh environment

  • C
  • D
    • Nr D Order code 71021743

      Kit Com ModbusRS485+stat.In 2Interf.Ex

      53/83/84/65/8CN/8DF

    • Nr D Order code 71039485

      Kit I/O Modb.RS485+Stat.In 2Interf.HE EX

      53/83/84/8CN/8DF HE = Harsh environment

    • Nr D Order code 50108002

      Kit I/O Profib. DP+Stat.In 2 Interf. Ex

      53/55/83/93

    • Nr D Order code 71039486

      Kit I/O Profib.DP+Stat.In 2 Interf.HE EX

      53/55/83 HE = harsh environment

    • Nr D Order code 50096833

      Kit Commodul current out 3 Interface Ex

      53/55/8X/93/65

    • Nr D Order code 71039477

      Kit I/O current out 3 Interface HE EX

      53/55/8X HE = harsh environment

    • Nr D Order code 71105712

      Kit I/O Modul 53/83 Ethernet

      Including Subprint Ethernet

  • 2
  • 3
  • 4
  • 5
  • 6
  • 37
  • J
    • Nr J Order code 50096755

      Kit display modul Wall enclosure

      53/55/83/84/93/8CN/8DF

  • E
  • 21
  • G
  • 19
  • 18
  • A
    • Nr A Order code 50098018

      Kit connection board D/E/L/P/S/W FS

      Usage: 10/50/51/53/55/400/800

    • Nr A Order code 71039497

      Kit connection board D/E/L/P/S/W FS HE

      Usage: 10/50/53/55 HE = harsh environment

  • 29
  • 30
  • 1
  • S
    • Nr S Order code 71003948

      Kit S-Dat Promag 53 programmed

      Serialnumber is forceful required

  • 8
  • 9
  • 10
    • Nr 10 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 26
    • Nr 26 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

  • 15
  • 12
  • 14
  • 13
  • 20
  • 11
  • 22
    • Nr 22 Order code 50098020

      Kit parts housing compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W

  • 24
    • Nr 24 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 25
    • Nr 25 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 23
    • Nr 23 Order code 50098024

      Kit housing gasket compact Stnd/HT

      Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code 53XXX-

      Promag 53, transmitter

    • Order code DK5UI-

      Promag 53, retro fit kit In/Output

      A retrofit kit consists of an instruction sheet, meter documentation, retrofit label, connection label and the exchangeable I/O modules.

    • Order code DK5WM-

      Transmitter Promag, mounting set

      10/50/51/53/55/800

    • Order code DK5GC-

      Promag L/W/P/S,E, grounding cable kit

      A kit includes 2 cables

    • Order code DK5GD-

      Promag, grounding disc/protection disc

      Includes 1 grounding disc/protection disc

    • Order code FXA193-

      Serviceinterface FXA193

      The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.

    • Order code DK5SO-

      Promag 53/55, software package

      Chip for release of software functionality. Note: The license is locked to a specific serial number (S-DAT).

  • Successor