Specs at a glance
-
Measured variables
Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
-
Measuring range
Gas Velocity: 0 ... ± 40 m/s
Field of application
FLOWSIC100 was designed for emission monitoring tasks. The "H" versions are suitable for stacks with large diameters and applications with high dust content. The ultrasonic transducers of the "PR" probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The "AC" versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged "Px" versions are used for gases with high concentrations of sticky or wet dust.
Emission monitoring in the chemical and hydrocarbon processing (HPI) industry
Emission measurement in the processing industry (cement, iron and steel, glass)
Device properties:
Rugged titanium converters for long service life
Corrosion-resistant material for use with aggressive gases (option)
Integrated measurement via duct diameter for types H, M, and S
Probe version PR for cost-saving, single-sided installation in duct
Automated operational check with zero and reference point test
Benefits
Reliable flow measurement for ducts with small up to very large diameters
No purge air required for applications with gas temperatures up to 260 °C
Minimum operating and maintenance costs
Accurate measuring results under difficult measuring conditions
Measurement without pressure loss, therefore no influences on the process
User-friendly operation via SOPAS ET software
Reliable function monitoring due to enhanced diagnosis
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Ultrasonic transit time difference measurement
-
Measured variables
Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
-
Measuring range
Gas Velocity: 0 ... ± 40 m/s
-
Medium temperature range
–40 °C ... +260 °C
-
Operating pressure range
–100 hPa ... 100 hPa -
Nominal pipe size
0,15 ... 13m
-
Conformities
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
30. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
EN 16911-2
MCERTS
GOST -
Outputs
1 output:
0/2/4 ... 20 mA, + 750 Ω
Electrically isolated, up to five outputs when add-on modules are used (option) -
Digital Outputs
5 relay outputs (change-over contacts), potential-free:
+ 48 V, 1 A
Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle" -
Digital communication
ASCII RS-485 (via optional interface module)
RTU RS-485 (via optional interface module)
TCP (via optional interface module)
Profibus (Via optional interface module)
-
-
Operating Instruction (BA)
FLOWSIC100
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Flow Rate Measuring Device
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
11.7 MB
File name:
8029810_1IK6_OI_FLOWSIC100_en_V4-0_2024-04_EHS.pdf
-
-
-
Operating Instruction (BA)
FLOWSIC100 Transmitter
-
Operating Instruction (BA)
English version - 12/2024New version available in EnglishGas Flow Rate Measuring Device
EN 18/12/2024Language:
English
Version:
18/12/2024
File size:
5.3 MB
File name:
8030364_AE00_OI_FLOWSIC100_Transmitter_en_V1-0_2023-05_EHS.pdf
-
-
-
Ex Safety Instruction (XA)
Safety Information
-
Ex Safety Instruction (XA)
English version - 01/2025New version available in Englishfor non-Ex analyzer devices
(multi-lingual, also in DE, BG, CS, DA, EL, ES, ET, FI, FR, HR, HU, IT,
LT, LV, NL, NO, PL, PT, RO, RU, SK, SL, SV)Language:
English
Version:
01/01/2025
File size:
2.4 MB
File name:
8030257_XA_Safety_Information_non-Ex_ml_V1-0_2016-06_WEB.pdf
-
-
-
Special Documentation (SD)
SOPAS ET 3.0 – Engineering Tool
-
Special Documentation (SD)
English version - 01/2025New version available in EnglishConnection establishment
Information on using the programEN 01/01/2025Language:
English
Version:
01/01/2025
File size:
993.3 KB
File name:
8031475_AE00_SD_SOPAS_3-0_V1-0_en_2016-05_EHS.pdf
-
-
-
Industry Solution (SO)
Solutions for chemicals, petrochemicals and refineries
-
Industry Solution (SO)
English version - 01/2025New version available in EnglishEndress+Hauser offers a broad product portfolio of continuous gas analyzers using state-of-the-art technologies.
Language:
English
Version:
01/01/2025
File size:
3.1 MB
File name:
8030415_CPR_en_V1-0_2025.01_EHS.pdf
-
-
-
Industry Solution (SO)
Solutions for waste-to-energy plants
-
Industry Solution (SO)
English version - 01/2025New version available in EnglishEndress+Hauser offers ideal automation and safety solutions for collection, sorting and recycling of waste.
Language:
English
Version:
01/01/2025
File size:
2.4 MB
File name:
8030416_SO_Waste_en_V1-0_2025.01_EHS.pdf
-
-
-
Industry Solution (SO)
Solutions for gas-fired power plants
-
Industry Solution (SO)
English version - 01/2025New version available in EnglishWith our broad range of solutions Endress+Hauser has proven applicability in the entire power generation process, from gas flow to
combustion efficiency to emissions monitoring.Language:
English
Version:
01/01/2025
File size:
4.2 MB
File name:
8030417_SO_Power_en_V1-0_2025.01_EHS.pdf
-
-
-
Competence Brochure (CP)
Soluzioni per il monitoraggio delle emissioni
-
Competence Brochure (CP)
Italian version - 05/2025New version available in EnglishSoluzioni per il monitoraggio delle
emissioni
Ampio portfolio e vasta esperienzaLanguage:
Italian
Version:
27/05/2025
File size:
4.5 MB
File name:
CP01596C16IT01.25-00.pdf
-
-
-
Competence Brochure (CP)
排出ガス監視ソリューション 幅広い製品群と長年にわたる実績
-
Competence Brochure (CP)
Japanese version - 09/2025New version available in English排出ガス監視、測定原理と技術、国際的な要件とサービス、選択ガイド、そして測定装置の一覧をまとめたパンフレット
Language:
Japanese
Version:
24/09/2025
File size:
11.1 MB
File name:
CP01596CJA_0125_Emission Monitoring Solutions.pdf
-
-
-
Competence Brochure (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
-
Competence Brochure (CP)
English version - 01/2025New version available in EnglishAn overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceLanguage:
English
Version:
01/01/2025
File size:
9.9 MB
File name:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons